Comparative analysis between the use of lattice towers and polygonal monopoles in SNEL SA's power grid network
DOI:
https://doi.org/10.59228/rcst.025.v4.i4.198Keywords:
Pylons, monopods, security and performance of electrical infrastructures, Impax software, vandalismAbstract
The comparative study on the use of lattice towers versus pylygonal monopods in SNEL SA's high-voltage transmission grid network is of paramount importance in determining the conditions for safety, reliability, operation and maintenance. The main aim is to overcome the growing phenomenon of vandalism, such as the theft of galvanized angle irons, bolts, copper conductors and earth counterweight wires from electrical infrastructures, leading to the collapse of lattice towers and the unavailability of SNEL SA's power transmission lines. The use of conical monopods offers the following advantages: Aesthetics, can be installed in urban areas, small footprint, rapid installation, dismantling and reuse possible, one-day installation, reduced number of parts for assembly, low maintenance costs spread over several years, resistance to vandalism, no natural aggression and environmental impact. The complete cost of building one kilometer of line is 1.25 k€/km with a conical monopole, compared with 1 k€/km for a lattice tower, resulting in an installation cost variation of 20%.
How to cite
APA
Mwanda Mizengi, Léon, Mampuya Nzita, André (2025). Comparative analysis between the use of lattice towers and polygonal monopoles in SNEL SA's power grid network. Congolese Journal of Science and Technology, 4(4), 718-728. https://doi.org/
Vancouver
Mwanda Mizengi L, Mampuya Nzita A. Comparative analysis between the use of lattice towers and polygonal monopoles in SNEL SA's power grid network. CJST. 2025;4(4):718-728. doi:10.59228/rcst.025.v4.i4.198
BibTeX
@article{rcst611,
author = {Mwanda Mizengi, Léon and Mampuya Nzita, André},
title = {Comparative analysis between the use of lattice towers and polygonal monopoles in SNEL SA's power grid network},
journal = {Congolese Journal of Science and Technology},
year = {2025},
volume = {4},
number = {4},
pages = {718--728},
doi = {10.59228/rcst.025.v4.i4.198},
url = {https://rcst.cd/index.php/rcst/en/article/view/611}
}
RIS
TY - JOUR AU - Mwanda Mizengi, Léon AU - Mampuya Nzita, André TI - Comparative analysis between the use of lattice towers and polygonal monopoles in SNEL SA's power grid network JO - Congolese Journal of Science and Technology PY - 2025 VL - 4 IS - 4 SP - 718 EP - 728 DO - 10.59228/rcst.025.v4.i4.198 UR - https://rcst.cd/index.php/rcst/en/article/view/611 ER -
Downloads
References
Albayrak, U., Morshid, L. (2020). Evaluation of Seismic Performance of Steel Lattice Transmission Towers. Civil Engineering Journal, (10), 2024-2044. http://dx.doi.org/10.28991/cej2020-03091600
Batut, J. (1987). Reliability of the power grid. Cahier / Groupe Réseaux, 3(9), 33–42.
https://doi.org/10.3406/flux.1987.1111
Bezas, M.-Z., Jaspart, J.-P., Vayas, J.-F. (2022).
Demonceau, Design recommendations for the stability of transmission steel lattice towers.
Engineering Structures, 252.113603.
https://doi.org/10.1016/j.engstruct.2021.113603.
Bonnefille, R. (1976). Linear Electrical Networks.
Conversion of Electrical Energy.
https://doi.org/10.51257/a-v1-d60
Chanal, A. (2018). Overhead Lines - Dimensioning.
Electrical Networks and Applications.
https://doi.org/10.51257/a-v2-d4421
Clerfeuille, J.-P,Vitet, S.,Lebrevelec, C. (2000).
Network defense plan against major incidents.
Electrical Networks and Applications, 1-6.
https://doi.org/10.51257/a-v1-d4807
de Beaune, S.A. (2013). Introduction: Aesthetics of the technical gesture. Gradhiva, 17, 4–25.
https://doi.org/10.4000/gradhiva.2556
Guillaume, A., Atya, M.A., Hesse, A. (1995). Map of the resistivities of the subsoil on the eastern outskirts of the Ramesseum (Luxor, Egypt).
Revue d’Archéométrie, 19(1), 19–24.
https://doi.org/10.3406/arsci.1995.924
Kumar, A., Hussain, D.M.A. (2018). HVDC (high voltage direct current) transmission system: a review article. Gyancity Journal of Engineering and Technology, 4(2), 1–10.
https://doi.org/10.21058/gjet.2018.42001
L’Ouvrier Moderne, Calculation of a pylon for the transmission of electrical energy, 4(10), 403–407, https://doi.org/10.1051/mattech/192204100403
Li, T., Guo, L., Ma, R., Gai, X., Wang, W. (2018). Fullscale tests and numerical simulations of failure mechanism of power transmission towers." International Journal of Structural Stability and Dynamics, 18(09), 1850109.
http://dx.doi.org/10.1142/s0219455418501092. .
Rudervall, R., Charpentier, J-P., Sharma, R. (2000).
High voltage direct current (HVDC) transmission systems technology review paper. Energy week, -19, 2000.
Wu, D., Cao, H., Li, D. and Yang, S. (2020). EnergyEfficient Reconstruction Method for Transmission Lines Galloping with Conditional Generative Adversarial Network. In IEEE Access, , 17310-17319.
http://dx.doi.org/10.1109/ACCESS.2020.296673
Zheng, J.-Y. , Shen, Q.-H. , Liu, X.-H. (2022).
Investigation of the galloping characteristics of multi-span ice-covered conductors. in IEEE Access,10, 64580-64600.
http://dx.doi.org/10.1109/ACCESS.2022.318316
Zhu, K. (2023). The optimization of the structure design of the transmission line pole tower body.
Advances in engineering technology research, https://doi.org/10.56028/aetr.3.1.794
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Mwanda & Mampuya
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.